Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas
See MSRP-1 Sheet or Check Spears® On-line Catalog @ www.spearsmfg.com for Pricing
Page 54
Valves Product True Union 2000 Industrial Ball Check Valves
Print this Book
True Union 2000 Industrial Ball Check Valves
Socket Style
Pressure Rating @ 73°F (23°C), Water
1/2" - 4" 235 psi
6" - 8" 150 psi
All Flanged 150 psi
Maximum Service Temperature
PVC = 140°F (60°C)
CPVC = 200°F (93°C)
Temperature/Pressure De-ratings Apply
Rated for Vacuum Service
All Valves assembled with Silicone-Free, Water Soluble Lubricant. Contact Spears® for MSRP & Availability on Custom Elastomer Seals. See Ball Valve Accessories & Repair Kits Section for Additional Options and Features
General Installation Information: Ball check valves may be installed in either horizontal or vertical position. A minimum of ten (10) pipe diameters' distance maintained from any pump or other source of turbulence. Check valves MUST be installed with the valve's FLOW arrow pointing in the direction of flow.
Maximum Service Temperature
PVC = 140°F (60°C)
CPVC = 200°F (93°C)
Temperature/Pressure De-ratings Apply
Rated for Vacuum Service
All Valves assembled with Silicone-Free, Water Soluble Lubricant
6" Venturied Valves are 4" Ball Check Valves equipped with 4x6 End Connectors.
General Installation Information: Ball check valves may be installed in either horizontal or vertical position. A minimum of ten (10) pipe diameters' distance maintained from any pump or other source of turbulence. Check valves MUST be installed with the valve's FLOW arrow pointing in the direction of flow.
Maximum Service Temperature
PVC = 140°F (60°C)
CPVC = 200°F (93°C)
Temperature/Pressure De-ratings Apply
General Installation Information: Butterfly Check Valve seating may be affected by normal system turbulence. Flow velocities should be limited to approximately 5 feet per second. Valves should be installed at least 5 pipe diameters away from any fitting, pump or other source of turbulence. If used as a foot valve, do not place near bottom of a tank. Butterfly type check valves should not be used in continuous cycling applications, such as with reciprocating pumps. This can result in premature failure of sealing membrane. In horizontal installations, always orient the Hinge Post Bolts visible on the external body in a vertical (top and bottom) position, perpendicular to flow. In vertical installations downstream from an elbow, flow velocities can be higher on the outer radius of the elbow. To avoid uneven butterfly plate loading, the Hinge Post Bolts should align with crotch and outer radius of elbow and NOT from side to side of the elbow.
Maximum Service Temperature
PVC = 140°F (60°C)
CPVC = 200°F (93°C)
PP = 180°F (82°C)
Temperature/Pressure De-ratings Apply
All Valves Assembled with Silicone-Free Lubricants
General Installation Information: Swing check valves are designed for horizontal installations, but may be installed in up-flow only vertical position. Check valves MUST be installed with the valve's FLOW arrow pointing in the direction of the flow. Do not install valve upside down. Flow velocity should not exceed 5 ft./sec.
Industrial Swing Check Valve Accessory and Repair Kits
Repair Kits include:
1-Bonnet O-ring
1-Disc O-ring
1-Seat O-ring
1-Plug O-ring
1-Arm Plug O-ring
Industrial Swing Check Valve Repair Kits
Size
EPDM
FKM
Std Pk
Mstr Pk
Prod Code
3/4
SK-ERK-007MSRP = 54.34
SK-VRK-007MSRP = 66.28
1
10
299
1
SK-ERK-010MSRP = 71.02
SK-VRK-010MSRP = 86.59
1
10
299
1-1/2 & 1-1/4
SK-ERK-015MSRP = 169.79
SK-VRK-015MSRP = 214.72
1
10
299
2
SK-ERK-020MSRP = 182.25
SK-VRK-020MSRP = 222.24
1
10
299
2-1/2
SK-ERK-025MSRP = 192.75
SK-VRK-025MSRP = 246.71
1
10
299
3
SK-ERK-030MSRP = 218.54
SK-VRK-030MSRP = 266.66
1
10
299
4
SK-ERK-040MSRP = 238.44
SK-VRK-040MSRP = 290.75
1
10
299
6
SK-ERK-060MSRP = 473.91
SK-VRK-060MSRP = 559.45
1
10
299
8
SK-ERK-080MSRP = 596.32
SK-VRK-080MSRP = 723.41
1
10
299
Utility Swing Check Valves
Pressure Rating @ 73°F (23°C), Water
1/2" - 4" Full Flow (open) 150 psi
Back Pressure (closed) 75 psi
6" - 8" Full Flow (open) 100 psi
Back Pressure (closed) 50 psi
Maximum Service Temperature
140°F (60°C)
Temperature/Pressure De-ratings Apply
EPDM Seat
General Installation Information: Swing check valves are designed for horizontal installations, but may be installed in an up-flow only vertical position. Check valves MUST be installed with the valve's FLOW arrow pointing in the direction of the flow. Do not install valve upside down. Flow velocity should not exceed 5 ft./sec. Minimum opening pressure less than 0.5 psi.
Pressure Rating @ 73°F (23°C), Water
Full Flow (open) 150 psi
Back Pressure (closed) 75 psi
Maximum Service Temperature
140°F (60°C)
Temperature/Pressure De-ratings Apply
EPDM Seat
General Installation Information: Swing check valves are designed for horizontal installations, but may be installed in an up-flow only vertical position. Check valves MUST be installed with the valve's FLOW arrow pointing in the direction of the flow. Do not install valve upside down. Flow velocity should not exceed 5 ft./sec. Minimum opening pressure less than 0.5 psi.
Pressure Rating @ 73°F (23°C), Water
Full Flow (open) 150 psi
Back Pressure (closed) 75 psi
Maximum Service Temperature
140°F (60°C)
Temperature/Pressure De-ratings Apply
Standard Swing Check Assembly Maintains a Positive Seal
Convenient Compression Ends for Quick Connections
Engineered for Maximum Flow, Quick Response & Positive Shutoff
Excellent for Pool & Spa, OEM and General Purpose Applications
Compact, Space-Saving Design
Replaceable PVC White or Clear Sealed Unit
High Grade EPDM Seat
Suitable for Horizontal or Vertical Up-flow Installations
Pressure Rated to 150 psi @ 73°F Full Flow (open), 75 psi Back Pressure (closed)
Maximum Service Temperature 140°F (temperature/pressure de-ratings apply)
General Installation Information: Swing check valves are designed for horizontal installations, but may be installed in up-flow only vertical position. Check valves MUST be installed with the valve's FLOW arrow pointing in the direction of the flow. Do not install valve upside down. Flow velocity should not exceed 5 ft./sec. Minimum opening pressure less than 0.5 psi.
1 CCW-20 - Wrench also fits 2-1/2" Coupling Body 2 CCW-30 - Wrench also fits 4" Coupling Body
Compression Coupling Nut Wrench Sets
Part Number
Size
Std Pk
Mstr Ctn
Prod Code
CCW-000MSRP = 206.11
Set
1
25
299
Complete Set of Wrenches, Sizes 1/2" - 3"
Utility Spring Check Valves
(Spring Assisted Swing Check)
Pressure Rating @ 73°F (23°C), Water
Full Flow (open) 150 psi
Back Pressure (closed) 75 psi
Maximum Service Temperature
140°F (60°C)
Temperature/Pressure De-ratings Apply
EPDM Seat
Stainless Steel Spring Assisted (non-adjustable)
General Installation Information: Spring check valves are designed for horizontal installations, but may be installed in an up-flow only vertical position. Check valves MUST be installed with the valve's FLOW arrow pointing in the direction of the flow. Do not install valve upside down. Flow velocity should not exceed 5 ft./sec. Minimum opening pressure less than 0.5 psi.
PVC White Spring Check (Spring Assisted Swing Check)
Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas
Spears® Manufacturing Company
See MSRP-1 Sheet or Check Spears® On-line Catalog @ www.spearsmfg.com for Pricing
Valves Product True Union Utility Spring Check Valves & Diaphragm Check Valves
Print this Book
True Union Utility Spring Check Valves
Pressure Rating @ 73°F (23°C), Water
Full Flow (open) 150 psi
Back Pressure (closed) 75 psi Maximum Service Temperature140°F (60°C) Temperature/Pressure De-ratings Apply EPDM Seat Stainless Steel Spring Assisted (non-adjustable)
General Installation Information: Spring check valves are designed for horizontal installations, but may be installed in an up-flow only vertical position. Check valves MUST be installed with the valve's FLOW arrow pointing in the direction of the flow. Do not install valve upside down. Flow velocity should not exceed 5 ft./sec. Minimum opening pressure less than 0.5 psi.
PVC White True Union Spring Check (Spring Assisted Swing Check)
General Installation Information: Diaphragm Check Valves have "normally closed" operation with 1 - 1-1/2 psi opening pressure and can be mounted in any position. Check valves MUST be installed with the valve's FLOW arrow pointing in the direction of the flow. Flow velocity should not exceed 5 ft./sec.
Made in the U.S.A.
Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas
See MSRP-1 Sheet or Check Spears® On-line Catalog @ www.spearsmfg.com for Pricing
Page 66
Valves Product PVC In-line Adjustable Spring Check Valves
Print this Book
PVC In-line Adjustable Spring Check Valves
Fipt x Mipt
Mipt x Fipt
Fipt x Fipt
Pressure Rating @ 73°F (23°C), Water
200 psi
Maximum Service Temperature
PVC = 140°F (60°C)
Temperature/Pressure De-ratings Apply
2 - 14 lbs. Adjustable Spring Tension
(5 to 32 feet of head)
Factory Preset to Approx. 5 psi
(12 feet of head)
Each full turn of adjustment nut = 1 psi
(2.3 feet of head)
Stainless Steel Adjustment Hardware