Schedule 80 PVC Technical
Schedule 80 PVC Pipe - Gray, Clear
Print this Book
Print this Book

Schedule 80 PVC Pipe - Gray
 
ENGINEERING GUIDE
Contact Spears® for any Information not found.
Schedule 80 PVC Technical
Schedule 80 PVC Pipe Dimensions & Pressure Ratings
Print this Book
Print this Book
Schedule 80 Pipe Dimensions & Pressure Ratings
Nom. Pipe Size (in) O.D. Average I.D. Min. Wall Nominal Wt./Ft. Maximum.
W.P. PSI*
1/8 .405 .195 0.095 0.063 1230
1/4 .540 .282 0.119 0.105 1130
3/8 .675 .403 0.126 0.146 920
1/2 .840 .526 0.147 0.213 850
3/4 1.050 .722 0.154 0.289 690
1 1.315 .936 0.179 0.424 630
1-1/4 1.660 1.255 0.191 0.586 520
1-1/2 1.900 1.476 0.200 0.711 470
2 2.375 1.913 0.218 0.984 400
2-1/2 2.875 2.290 0.276 1.500 420
3 3.500 2.864 0.300 2.010 370
3-1/2 4.000 3.326 0.318 2.452 350
4 4.500 3.786 0.337 2.938 320
5 5.563 4.768 0.375 4.078 290
6 6.625 5.709 0.432 5.610 280
8 8.625 7.565 0.500 8.522 250
10 10.750 9.493 0.593 12.635 230
12 12.750 11.294 0.687 17.384 230
14 14.000 12.410 0.750 20.852 220
16 16.000 14.213 0.843 26.810 220
18 18.000 16.014 0.937 33.544 220
20 20.000 17.814 1.031 41.047 220
24 24.000 21.418 1.218 58.233 210
Maximum PVC Service Temperature 140°F
Pressure De-rating at Elevated Temperatures
The pressure ratings given above are for water, non-shock, @ 73°F. The specified derating factors for PVC are suitable for pipe conveying water at elevated temperatures. To determine elevated temperature rating, multiply 73°F [23°C] pressure rating by appropriate factor shown in the table for desired operating temperature. When working near maximum specified temperature, solvent cement joints are recommended in place of threaded connections. Where disassembly is required at elevated temperatures, use Spears® Special reinforced (SR) adapters, flanges, unions or grooved coupling connections. Spears® recommends that only Schedule 80 or heavier wall thickness pipe should be threaded.
PVC Pipe
Operating Temp (°F) De-Rating Factor
73 1.00
80 0.88
90 0.75
100 0.62
110 0.51
120 0.40
130 0.31
140 0.22
EX: 2" PVC SCHEDULE 80 @ 120°F = 400 psi x 0.40 = 160 psi max. @ 120°F.
See Plastic Pipe Engineering Guide for additional information
Schedule 80 PVC Technical
Schedule 80 PVC Pipe Dimensions & Pressure Ratings
Print this Book
Print this Book

Pipe - PVC Schedule 80 Plain End
10' Lengths
Pipe - PVC Schedule 80 Plain End
Part NumberSizeLAVG.O.D.Minimum
Wall
Approx. Wt.
(Lbs./Ft)
PD-800-001-101/810.405.095 .06
PD-800-002-101/410.540.119 .10
PD-800-003-103/810.675.126 .14
PD-800-005-101/210.840.147 .21
PD-800-007-103/4101.050.154 .29
PD-800-010-101101.315.179 .40
PD-800-012-101-1/4101.660.191 .58
PD-800-015-101-1/2101.900.200 .70
PD-800-020-102102.375.218 .98
PD-800-025-102-1/2102.875.276 1.58
PD-800-030-103103.500.300 1.95
PD-800-040-104104.500.337 2.84
PD-800-060-106106.625.432 5.61
PD-800-080-108108.625.500 8.52
PD-800-100-10101010.750.593 12.34
PD-800-120-10121012.750.687 17.38
PD-800-140-10141014.750 19.79
PD-800-160-10161016.843 25.44
PD-800-180-10181018.937 33.54
PD-800-200-102010201.031 41.04
PD-800-240-102410241.281 58.23

Pipe - PVC Schedule 80 Plain End
20' Lengths
Pipe - PVC Schedule 80 Plain End
Part NumberSizeLAVG.O.D.Minimum
Wall
Approx. Wt.
(Lbs./Ft)
PD-800-0011/820.405.095 .06
PD-800-0021/420.540.119 .10
PD-800-0033/820.675.126 .14
PD-800-0051/220.840.147 .21
PD-800-0073/4201.050.154 .29
PD-800-0101201.315.179 .40
PD-800-0121-1/4201.660.191 .58
PD-800-0151-1/2201.900.200 .70
PD-800-0202202.375.218 .98
PD-800-0252-1/2202.875.276 1.58
Schedule 80 PVC Technical
Schedule 80 PVC Pipe Dimensions & Pressure Ratings
Print this Book
Print this Book
Pipe - PVC Schedule 80 Plain End
20' Lengths
Pipe - PVC Schedule 80 Plain End
(Continued)
Part NumberSizeLAVG.O.D.Minimum
Wall
Approx. Wt.
(Lbs./Ft)
PD-800-0303203.500.300 1.95
PD-800-0404204.500.337 2.84
PD-800-0505205.563.375 4.07
PD-800-0606206.625.432 5.61
PD-800-0808208.625.500 8.52
PD-800-100102010.750.593 12.34
PD-800-120122012.750.687 17.38
PD-800-140142014.750 19.79
PD-800-160162016.843 25.44
PD-800-180182018.937 33.54
PD-800-2002020201.031 41.04
PD-800-2402420241.218 58.23

Pipe - Clear PVC Schedule 80 Plain End
10' Lengths
Pipe - Clear PVC Schedule 80 Plain End
Part NumberSizeLAVG.O.D.Minimum
Wall
Approx. Wt.
(Lbs./Ft)
PD-800-002L-101/410.540.119 .08
PD-800-003L-103/810.675.126 .14
PD-800-005L-101/210.840.147 .21
PD-800-007L-103/4101.050.154 .29
PD-800-010L-101101.315.179 .39
PD-800-012L-101-1/4101.660.191 .58
PD-800-015L-101-1/2101.900.200 .70
PD-800-020L-102102.375.218 .98
PD-800-025L-102-1/2102.875.276 1.58
PD-800-030L-103103.500.300 1.95
PD-800-040L-104104.500.337 2.84
PD-800-060L-106106.625.432 5.61

Spears Super Sourcebook prints best when the margins are set to our specifications and the headers and footers are turned off.
The Spears Product Price Schedules will print on standard 8.5 x 11 paper with the following changes to your browsers page setup.

For Microsoft Internet Explorer Version 8 & 9:
  1. Select File/Page Setup
  2. Set Orientation to Portrait.
  3. Check “Print Background Colors and Images.”
  4. Set the Margins as follows:
  5. Select “-Empty-” in all the Header and Footer dropdown boxes.
  6. Click OK.